MegaFuga D101

Cement based joint filler, applied to the ceramic joints with gaps, ranging between 1 and 6 mm.

MegaFuga is suitable for use on the joints with gaps, ranging between 1 and 6 mm on such floors coated with ceramic, natural stone, granite ceramic and marble and in horizontal and vertical joint gaps in indoors spaces.

Reference Standards

a. Certifications / Standards
• TS EN 13888
b. Ministry of Public Works and Settlement Item No.
Ministry of Public Works and Settlement Item No.: 04.013/2

Application Surfaces
Indoors Walls;
Ceramic
Natural stone
Marble
Granite
Indoors and Outdoors Floors;
Ceramic
Natural stone
Marble
Granite

Surface Preparation :
The surface coating materials should have been bonded minimum 24 hours in advance.
Joint application should not be initiated before the adhesive is completely dehydrated.
Coating surface and joint gaps should have been cleaned and cleansed of oil, dirt and dust.
The joint gaps should be moisturized in order to maintain the fixed water absorption of vertical and horizontal parts.

Application Methods :
MegaFuga should be filled into joint gaps with a plastic or rubber based joint trowel through parallel and crosswise movements.
The residuary on the mortar’s surface should be scraped with a soft tip joint trowel or a moisturized sponge, and the thin layer of joint, which may have remained on the surface, should be thoroughly cleaned by wiping with a moist sponge after roughly 20 minute standby time, depending on the ambient temperature.
Surface smoothening and cleaning should be performed with a dry cloth before MegaFuga dries completely.

Application Recommendations :
The adhesive and the surface behind the coating should be completely dehumidified in order to prevent yellowing in the case of white joints and undulation in the case of colorful joints after the application.
The application thickness of the joint filler should be identical for both floor and wall applications.
MegaFuga Guard should be used in order for the prevention of the discoloration of the joint fillers used on such frequently cleaned surfaces and floors as kitchen counters and for the same to be lasting.
Such cleaning supplies as bleach, hydrochloric acid and lime remover should not be used in order to ensure that the joint fillings are not damaged. The joint gaps should be cleaned with MegaClean.
The product should, once mixed, be used before the expiration of its pot life. Any mortar, the pot life of which has expired, should not be used during the application.
Any such foreign substance as lime, cement or plaster should not be added to the mortar prepared.
Any extra water should not be added to the mixture.
The product should not be applied on unsound surfaces. The soundness and the load bearing capacity of old surfaces should be checked prior to adhesion.
The surface should be preserved from air currents and water contact during and after the application.
The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing.
Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +30°C whilst at application.

Colour Options

Close

MegaFuga 2K D104

Cement based, elastic joint filler resistant to water, frost and temperature changes.

MegaFuga 2K is suitable for use in cases, where extra water repelling is required, for the filling of the gaps amongst ceramics, marbles, natural stones and mosaics, bonded horizontally and vertically. The product does not cause deflections or crackage on the surface it is applied. It enables a smooth surface thanks to its joint thickness.

Reference Standards

a. Certifications / Standards
• TS EN 13888

Application Surfaces
Indoors and Outdoors Walls;
Ceramic
Natural stone
Marble
Granite
Indoors and Outdoors Floors;
Ceramic
Natural stone
Marble
Granite

Surface Preparation :
The surface coating materials should have been bonded minimum 24 hours in advance.
Joint application should not be initiated before the adhesive is completely dehydrated.
Coating surface and joint gaps should have been cleaned and cleansed of oil, dirt and dust.
The joint gaps should be moisturized in order to maintain the fixed water absorption of vertical and horizontal parts.

Application Methods :
MegaFuga 2K joint filler should be filled into joint gaps with a plastic or rubber based joint trowel through parallel and crosswise movements.
The residuary on the mortar’s surface should be scraped with a soft-tip scraper or a scraper with moisturized sponge on the tip, and the thin layer of joint, which may have remained on the surface, should be thoroughly cleaned by wiping with a moist sponge after roughly 20 minute standby time, depending on the ambient temperature.
Surface smoothening and cleaning should be performed with a dry cloth before MegaFuga Flex dries completely.

Application Recommendations :
Due consideration should be given to the required mixing ratios for the product. Otherwise, the expected resistance cannot be obtained.
The adhesive and the surface behind the coating should be completely dehumidified in order to prevent yellowing of the joints after the application.
The application thickness of the joint filler should be identical for both floor and wall applications.
Due care should be given to prevent the exposure of the material to direct sunlight in hot weather conditions.
The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance.
The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing.
The surface should be protected from air currents during and after the application.
The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours.
The product should, once mixed, be used before the expiration of its pot life. Any joint filler, the pot life of which has expired, should not be used during the application.
Any such foreign substance as lime, cement or plaster should not be added to the product, which prepared with two compounds.
MegaFuga Guard should be used in order for the prevention of the discoloration of the joint fillers used on such frequently cleaned surfaces and floors as kitchen counters and for the same to be lasting.
Such cleaning supplies as bleach, hydrochloric acid and lime remover should not be used in order to ensure that the joint fillings are not damaged. The joint gaps should be cleaned with MegaClean.
Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +30°C whilst at application.

 

Close

MegaFuga Flex D103

Cement based, elastic and antibacterial joint filler with high polymer additive, which is suitable for application to joint gaps, ranging between 2 and 10 mm, in indoors and outdoors spaces, and is resistant to temperature changes and also water resistant.

MegaFuga Flex is suitable for use on all types of coating with joint gaps, ranging between 2 to 10 mm, on such floors applied with ceramic, natural stone, granite ceramic, marble etc., on such wet areas as bathrooms, terraces and pools, on such floors with floor heating, where extremely high temperature changes occur, on such floors that are exposed to busy pedestrian traffic and on horizontal and vertical joint gaps in indoors and outdoors spaces.

Reference Standards

a. Certifications / Standards
• TS EN 13888
b. Ministry of Public Works and Settlement Item No.
Ministry of Public Works and Settlement Item No.: 04.013/2

Application Surfaces
Indoors and Outdoors Walls;
Ceramic
Natural stone
Marble
Granite
Indoors and Outdoors Floors;
Ceramic
Natural stone
Marble
Granite

Surface Preparation :
The surface coating materials should have been bonded minimum 24 hours in advance.
Joint application should not be initiated before the adhesive is completely dehydrated.
Coating surface and joint gaps should have been cleaned and cleansed of oil, dirt and dust.
The joint gaps should be moisturized in order to maintain the fixed water absorption of vertical and horizontal parts.

Application Methods :
MegaFuga Flex joint filler should be filled into joint gaps with a plastic or rubber based joint trowel through parallel and crosswise movements.
The residuary on the mortar’s surface should be scraped with a soft-tip scraper or a scraper with moisturized sponge on the tip, and the thin layer of joint, which may have remained on the surface, should be thoroughly cleaned by wiping with a moist sponge after roughly 20 minute standby time, depending on the ambient temperature.
Surface smoothening and cleaning should be performed with a dry cloth before MegaFuga Flex dries completely.

Application Recommendations :
The adhesive and the surface behind the coating should be completely dehumidified in order to prevent yellowing in the case of white joints and undulation in the case of colorful joints after the application.
The application thickness of the joint filler should be identical for both floor and wall applications.
MegaFuga Guard should be used in order for the prevention of the discoloration of the joint fillers used on such frequently cleaned surfaces and floors as kitchen counters and for the same to be lasting.
Such cleaning supplies as bleach, hydrochloric acid and lime remover should not be used in order to ensure that the joint fillings are not damaged. The joint gaps should be cleaned with MegaClean.
The product should, once mixed, be used before the expiration of its pot life. Any product, the pot life of which has expired, should not be used during the application.
Any such foreign substance as lime, cement or plaster should not be added to the mortar prepared.
Any extra water should not be added to the mixture.
The product should not be applied on unsound surfaces. The soundness and the load bearing capacity of old surfaces should be checked prior to adhesion.
The surface should be preserved from air currents and water contact during and after the application.
The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing.
Due care should be taken to ensure that the material is not exposed to direct sunlight in hot weather conditions, and the product should be mixed with cold water.
The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance.
The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours.
Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +30°C whilst at application.

 

Colour Options

Close

MegaFuga Rustik D106

Cement based, elastic joint filler resistant to temperature changes, which is suitable for application to joint gaps, ranging between 4 to 20 mm, of ceramic, face tile and decorative coatings.

MegaFuga Rustik is suitable for use on large joint gaps of natural stone and face tile coatings for decorative purposes, and on vertical and horizontal surfaces in indoors and outdoors spaces.

Reference Standards

a. Certifications / Standards
• TS EN 13888

Application Surfaces
Indoors and Outdoors Walls;
Ceramic
Natural stone
Indoors and Outdoors Floors;
Ceramic
Natural stone
Face tile

Surface Preparation :
The surface coating materials should have been bonded minimum 24 hours in advance.
Joint application should not be initiated before the adhesive is completely dehydrated.
Coating surface and joint gaps should have been cleaned and cleansed of oil, dirt and dust.
The joint gaps should be moisturized in order to maintain the fixed water absorption of vertical and horizontal parts.

Application Methods :
based joint trowel or a caulking gun with due attention not to contaminate the surface of the coating material.
The residuary on the mortar’s surface should be scraped with a soft tip scraper or a scraper with moisturized sponge on the tip. In the case of the applications between face tiles, the surface of the joint filler should be shaped with a hand tool with round tip.
Surface smoothening should be performed before the product completely dries.

Application Recommendations :
Such cleaning supplies as bleach, hydrochloric acid and lime remover should not be used in order to ensure that the joint fillings are not damaged. The joint gaps are recommended to be cleaned with MegaClean.
The product should, once mixed, be used before the expiration of its pot life. Any product, the pot life of which has expired, should not be used during the application.
Any such foreign substance as lime, cement or plaster should not be added to the mortar prepared.
Any extra water should not be added to the mixture.
The product should not be applied on unsound surfaces. The soundness and the load bearing capacity of old surfaces should be checked prior to adhesion.
The surface should be preserved from air currents and water contact during and after the application.
The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing.
Due care should be taken to ensure that the material is not exposed to direct sunlight in hot weather conditions, and the product should be mixed with cold water.
The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance.
The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours.
Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +30°C whilst at application.

Colour Options

Close

MegaFuga Sil D102

Cement based, elastic and water repellent joint filler with polymer and silicon additives, which is suitable for application to joint gaps, ranging between 2 and 10 mm, in indoors and outdoors spaces, and is resistant to temperature changes and also water resistant.

MegaFuga Sil is suitable for use on the joints with gaps, ranging between 2 and 10 mm, on such floors coated with ceramic, natural stone, granite ceramic and marble, and on such wet areas as bathrooms, terraces and pools. It is suitable for use horizontal and vertical joint gaps on indoors and outdoors spaces.

Reference Standards

a. Certifications / Standards
• TS EN 13888
b. Ministry of Public Works and Settlement Item No.
Ministry of Public Works and Settlement Item No.: 04.013/2

Application Surfaces
Indoors Walls;
Natural stone
Marble
Granite
Indoors and Outdoors Floors;
Natural stone
Granite

Surface Preparation :
The surface coating materials should have been bonded minimum 24 hours in advance.
Joint application should not be initiated before the adhesive is completely dehydrated.
Coating surface and joint gaps should have been cleaned and cleansed of oil, dirt and dust.
The joint gaps should be moisturized in order to maintain the fixed water absorption of vertical and horizontal parts.

Application Methods :
MegaFuga Sil joint filler should be filled into joint gaps with a plastic or rubber based joint trowel through circular, parallel and crosswise movements.
The residuary on the mortar’s surface should be scraped with a soft-tip scraper or a scraper with moisturized sponge on the tip, and the thin layer of joint, which may have remained on the surface, should be thoroughly cleaned by wiping with a moist sponge after roughly 20 minute standby time, depending on the ambient temperature.
Surface smoothening and cleaning should be performed with a dry cloth before MegaFuga Sil dries completely.

Application Recommendations :
The adhesive and the surface behind the coating should be completely dehumidified in order to prevent yellowing in the case of white joints and undulation in the case of colorful joints after the application.
The application thickness of the joint filler should be identical for both floor and wall applications.
MegaFuga Guard should be used in order for the prevention of the discoloration of the joint fillers used on such frequently cleaned surfaces and floors as kitchen counters and for the same to be lasting.
Such cleaning supplies as bleach, hydrochloric acid and lime remover should not be used in order to ensure that the joint fillings are not damaged. The joint gaps should be cleaned with MegaClean.
The product should, once mixed, be used before the expiration of its pot life. Any mortar, the pot life of which has expired, should not be used during the application.
Any such foreign substance as lime, cement or plaster should not be added to the mortar prepared.
Any extra water should not be added to the mixture.
The product should not be applied on unsound surfaces. The soundness and the load bearing capacity of old surfaces should be checked prior to adhesion.
The surface should be preserved from air currents and water contact during and after the application.
The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing.
Due care should be taken to ensure that the material is not exposed to direct sunlight in hot weather conditions, and the product should be mixed with cold water.
The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance.
The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours.
Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +30°C whilst at application.

 

Colour Options

Close

MegaEpoxy D501

Epoxy resin based, double compound antibacterial ceramic adhesive and joint filler, which can be applied to joints, ranging between 3 and 15 mm, is resistant to acids and alkalis, has strong mechanical resistance and is suitable for contact with drinking water.

MegaEpoxy is used for the adhesion of antacid ceramic, industrial ceramic, granite, glass mosaic, glass brick and marble horizontally and vertically and the filling of horizontal and vertical joint gaps, ranging between 3 and 15 mm, in indoors and outdoors spaces on such floors with floor heating, where extremely high temperature changes occur, and in such spaces, where chemical resistance, impermeability and high mechanical resistance are required.
MegaEpoxy is fit for use in miscellaneous wet spaces and hygienic environments such as the food industry, milk, cheese and yogurt manufacturing shops, slaughter houses, dairy farms, integrated meat plants, wine distilleries and breweries, bottling and filling facilities, industrial kitchens, hospitals and laboratories, pharmaceutical and cosmetics industry, swimming pools containing salt and thermal water and waste water treatment plants.

Reference Standards

a. Certifications / Standards
• TS EN 13888

Application Surfaces
Indoors and Outdoors Walls;
Ceramic
Natural stone
Marble
Granite
Glass mosaic
Glass brick
Cement based plaster
Concrete
Metal
Indoors and Outdoors Floors;
Ceramic
Natural stone
Marble
Granite
Glass mosaic
Glass brick
Cement based trowel coating
Concrete
Metal

Surface Preparation :
The application surface should be dry, clean, sound and dust free, and should have been cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as mortar and cement residues should be scraped from the application surface.
It should be made sure that the joint gaps are dry and clean prior to joint filling application.
Coating surface and joint gaps should have been cleaned and cleansed of oil, dirt and dust.
The concrete surfaces should have completed the 28 day curing period. The surface humidity should not exceed 5 % during the application.
Expansion joints should be formed as necessary with due consideration of the movements, which may occur on the floor especially in extensive spaces and in such environments, where heat sources exist, on account of thermal and mechanical causes. Such joints should be sealed with Megaİzo PU Mastik LM or Megaİzo PU Mastik HM.
Any surface defects deeper than 2 cm should be repaired with MegaTamir Epo 24 hours in advance of adhesive mortar application.
In the case of wet space applications, waterproofing should be ensured with MegaIzo Lastik 10 on the surface, which should have been coated with the recommended primer, prior to ceramic flooring.

Application Methods :
In the cases, where MegaEpoxy is to be used as adhesive; the material should, subsequent to stirring, be poured on the surface and be spread as a homogenous layer of 2 to 3 mm thickness. The product should be applied and spread with a notched trowel that is suitable for the ceramic size and the characteristics of the surface.
In the cases, where MegaEpoxy is to be used as joint filler; the stirred material should be applied only to the joint gaps on the application surface with a suitable epoxy joint trowel made of hard rubber. The product should, then, be scraped to ensure that the joints are filled and sealed completely and that the surface is free from any residue.
Any residues of the material on ceramics should be removed with warm water with detergent (30O C – 40O C) within 15 to 20 minutes following the application. Coarse cleaning should be performed with an epoxy trowel and the fine cleaning should be performed with a sponge. The fine cleaning should be performed with a moist sponge through circular movements without applying extreme pressure on the surface.
Joint filling may be initiated minimum 24 hours after the adhesion.
In some cases, a secondary application may be necessary to fill the joints, which have not been thoroughly filled and pose low levels. In such cases, the secondary application is recommended to be performed within maximum 5 to 6 hours in order to ensure inter coat adhesion.

Application Recommendations :
In the case of the applications at temperatures lower than +10° C; the product should be kept in a warm environment minimum one day prior to the application in order to ensure easy application, and it should be made sure that the product is at room temperature during the application.
The product may pose increased thickening in cold weather conditions. In such cases, the normal thickness of the product may be restored by being moved to a warm environment or bathed in hot water (having the materials kept in a container filled with hot water prior to mixing).
The product should, once mixed, be used before the expiration of its pot life. Any product, the pot life of which has expired, should not be used during the application. Epoxy based products have limited pot lives; therefore, due consideration should be given to the fact that the pot life and dry times would shorten at high temperatures and lengthen at low temperatures.
Any such foreign substance as lime, cement or plaster should not be added to the product, which prepared with two compounds.
The product should not be applied on unsound surfaces. The soundness and the load bearing capacity of old surfaces should be checked prior to adhesion.
The surface should be preserved from air currents and water contact during and after the application.
The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing.
Due care should be taken to ensure that the material is not exposed to direct sunlight in hot weather conditions, and the product should be mixed with cold water.
The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance.
The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours.
Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +10° C and +30°C whilst at application.
The surface temperature should be minimum +3°C higher than the related dew point temperature.
The product should not be applied under such conditions, where the ambient temperature is lower than +10°C and the relative humidity is higher than 75 %.

Colour Options