Showing all 5 results

Show sidebar
Close

MegaClean K902

It’s a ready to use ceramic surface and joint cleaner, which is capable of rapidly cleaning any dirt and construction material residues on the surface of coating materials and on the joint fillings.

MegaClean is used for the cleaning of such coating materials as ceramic and granite, which have been contaminated by mortar, joint filling and cement-based construction residues, and for the coatings and joint fillings, which have been stained with such substances as coffee, tea and ink.

Application Surfaces
Indoors Wall Surfaces and Joints;
Ceramic
Granite
Indoors Floor Surfaces and Joints;
Ceramic
Granite

Surface Preparation :
• A pre-trial application should be performed in a small spot of the surface prior to the actual application.

Application Methods :
• The secondary coat of plaster should be applied minimum 24 hours after the application of MegaSıva Makine Serpme, after which the surface should be gauged and finished.

Application Recommendations :
• The cleaning process should be repeated where necessary in the case of excessively contaminated surfaces.
• The product should not be used for such coatings that are acid-sensitive (travertine, marble), glazed tiles and hand-made ceramics, fittings vulnerable to acid, and metals and metallic coated ceramic surfaces since it would cause color deformation.
• The application surface should not be excessively moist.
• Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +30°C whilst at application.

Close

MegaClean K902

It’s a ready to use ceramic surface and joint cleaner, which is capable of rapidly cleaning any dirt and construction material residues on the surface of coating materials and on the joint fillings.

MegaClean is used for the cleaning of such coating materials as ceramic and granite, which have been contaminated by mortar, joint filling and cement-based construction residues, and for the coatings and joint fillings, which have been stained with such substances as coffee, tea and ink.

Application Surfaces
Indoors Wall Surfaces and Joints;
Ceramic
Granite
Indoors Floor Surfaces and Joints;
Ceramic
Granite

Surface Preparation :
• A pre-trial application should be performed in a small spot of the surface prior to the actual application.

Application Methods :
• The secondary coat of plaster should be applied minimum 24 hours after the application of MegaSıva Makine Serpme, after which the surface should be gauged and finished.

Application Recommendations :
• The cleaning process should be repeated where necessary in the case of excessively contaminated surfaces.
• The product should not be used for such coatings that are acid-sensitive (travertine, marble), glazed tiles and hand-made ceramics, fittings vulnerable to acid, and metals and metallic coated ceramic surfaces since it would cause color deformation.
• The application surface should not be excessively moist.
• Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +30°C whilst at application.

Close

MegaFuga Guard K202

An environmental friendly release agent, which enables convenient release of concrete from the mold and so obtainment of concrete with smooth surface.

MegaFuga Guard is used on frequently cleaned surfaces and floors in all indoors and outdoors spaces in order for the preservation of the color of the joint fillings, which have been cleaned with MegaClean or recently applied.

Application Surfaces
Indoors and Outdoors Walls;
Ceramic
Granit
Natural stone and the like coating materials and joints
Indoors and Outdoors Floors;
Ceramic
Granit
Natural stone and the like coating materials and joints

Surface Preparation :
• The surface should be clean, robust and free from dust, and be cleaned from oil, dirt or any material that may adversely affect the application with MegaClean.
• The application surface should be dry and absorbent.

Application Methods :
• MegaFuga Guard should be applied to joint fillings minimum 48 hours after the application of joint filler.
• In the case of the applications before joint filling, due care should be taken to ensure that MegaFuga Guard contaminate the joint gaps.
• MegaFuga Guard can be applied on joint fillings by spraying directly thanks by way of spray bottle.
• MegaFuga Guard should be thoroughly spread on the joint filling with a cloth or sponge.
• MegaFuga Guard can be applied in a secondary coat shortly before the initial coat dries in order to ensure more effective protection.
• The surface of ceramic coating can be cleaned easily with a moist cloth or sponge once MegaFuga Guard dries completely.

Application Recommendations :
• The product should not be used for such coatings that are acid-sensitive (travertine, marble), glazed tiles and hand-made ceramics, fittings vulnerable to acid, and metals and metallic coated ceramic surfaces since it would cause color deformation.
• The surface should be preserved from air currents and water contact during and after the application.
• The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours.
• Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +35°C whilst at application.

Close

MegaLatex K201

Adherence enhancer, binder and waterproof additive for such materials as cement based mortar, trowel coating and plaster.

MegaLatex is used for any and all cement based mortar applications under construction site conditions, along with repair mortar applications for renovation purposes, along with trowel coating on the floors of industrial and large size spaces with heavy and busy traffic, along with plaster in pool applications, and along with repair mortars in beveling applications.

Reference Standards

a. Certifications / Standards
Ministry of Public Works and Settlement Item No.
Ministry of Public Works and Settlement Item No.: 04.613/1C

Application Surfaces
The product is used with cement based mortars (ceramic adhesives, plasters, trowel coatings and repair mortars).

Surface Preparation :
The product is used with cement based mortars (ceramic adhesives, plasters, trowel coatings and repair mortars); therefore, the surface should be prepared as appropriate for such applications.

Application Methods :
• MegaLatex should be added to the mixing water of such materials as cement based plaster, trowel coating and adhesive mortar in such volume that is equal to 30 % of the volume of the mixing water at minimum. The adherence, mechanical resistance and waterproofing of cement based plasters, trowel coatings and adhesives increase proportionally with the volume of MegaLatex added.

Application Recommendations :
• MegaLatex should not be used for such applications, which are performed under inappropriate ambient and surface conditions.
• Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +35°C whilst at application.

Close

MegaKalıp MY K903

An environmental friendly release agent, which enables convenient release of concrete from the mold and so obtainment of concrete with smooth surface.

MegaKalıp MY can be used for steel, plastic, plywood and wooden mold systems. The product enables the release of the concrete from the mold smoothly and free from stains.

Reference Standards

a. Certifications / Standards
TS 12153
b. Ministry of Public Works and Settlement Item No.
Ministry of Public Works and Settlement Item No.: 04.116/2

Application Surfaces
• Steel
• Plastic
• Plywood
• Wooden molds
• Tunnel – formed molds

Surface Preparation :
There should not be any chemical wastes or residues (diesel oil, gas etc.) on the mold surfaces, and particularly in the cases, where the release agent employed is changed, the surfaces must be cleaned to be free from any residues of any previous release agent used.

Application Methods :
The product is applied via spraying, roller or brush on clean mold surfaces. Due consideration should be given to apply minimum amount of product in the thinnest layer practicable.

Application Recommendations :
• Excessive use of oil would lead to the formation of stains on the concrete; therefore, any extra oil on the surface should be cleaned via a sponge, cloth etc.
• In case of highly absorbent surfaces, a second layer should be applied where necessary.
• Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +35°C whilst at application.