Showing 1–12 of 41 results

Show sidebar
Close

ARTEFIX E101

Cement based ceramic adhesive mortar with reduced slippage.

ARTEFIX is used for the adhesion of coating materials on sound and dust free cement based plaster and trowel coating with low water absorption. The product is used for the adhesion of coating materials in wall dimensions up to 25×40 cm and ceramic tile dimensions up to 33×33 cm horizontally and vertically in indoors spaces and horizontally in outdoors spaces.

Reference Standards

a. Certifications / Standards
• TS EN 12004
• CE
b. Ministry of Public Works and Settlement Item No.
Ministry of Public Works and Settlement Item No.: 04.013/1

Application Surfaces
Indoors Walls;
Cement based plaster
Indoors and Outdoors Floors;
Cement based trowel coating

Surface Preparation :
The application surface should be dry, clean, sound and dust free, and should have been cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as mortar and cement residues should be scraped from the application surface.
The dusty surface on the reverse side of the ceramic tile should be moisturized and cleaned.
The surface defects, which are deeper than 1 cm, should be repaired with MegaTamir İ or MegaTamir K 24 hours in advance of the adhesive mortar application. In the cases, where structural repair mortar should be used; MegaTamir İ Yapısal or MegaTamir K Yapısal should be preferred.
Upon the completion of the surface cleaning, MegaFilm primer should be applied in a single coat with a brush and be left to dry for 1 to 2 hours in order to enhance the bonding strength and stabilize the surface absorption.
In the case of wet space applications, waterproofing should be ensured with Megaİzo Lastik 10 on the surface, which should have been coated with the recommended primer, prior to ceramic flooring. Minimum class C2 adhesives should be preferred for such surfaces.

Application Methods :
ARTEFIX should be applied to the surface with the notched trowel determined with respect to the size of the ceramic tile and the structural condition of the surface.
Due care must be taken to ensure that ARTEFIX does not form a film layer on the surface during the application. In the cases of formation of film layer on the surface, the adhesive should be scraped off the surface and should never be used again.
The coating material should be placed on the surface and be ensured to settle thereon with a rubber tip hammer.
Joint filling should be initiated minimum 24 hours after the adhesion.
In the case of the applications with ceramic tiles with dimensions in excess of 20×20 cm in indoors and outdoors spaces; double side adhesion should be applied.
The product should not be used for ceramic tiles for floors larger than 33×33 cm and for walls larger than 25×40 cm.

Application Recommendations :
MegaLatex may be employed in order to enhance the performance of the product.
The product should, once mixed, be used before the expiration of its pot life. Any mortar, the pot life of which has expired, should not be used during the application.
Any such foreign substance as lime, cement or plaster should not be added to the mortar prepared.
Any extra water should not be added to the mixture.
The product should not be applied on unsound surfaces. The soundness and the load bearing capacity of old surfaces should be checked prior to adhesion.
The surface should be preserved from air currents and water contact during and after the application.
The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing.
Due care should be taken to ensure that the material is not exposed to direct sunlight in hot weather conditions, and the product should be mixed with cold water.
The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance.
The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours.
Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +35°C whilst at application.

Close

BRUFIX E102

Cement based ceramic adhesive mortar with reduced slippage.

BRUFIX is used for the adhesion of coating materials on sound and dust free cement based plaster and trowel coating with low water absorption. The product is used for the adhesion of coating materials in wall dimensions up to 25×40 cm and ceramic tile dimensions up to 33×33 cm horizontally and vertically in indoors spaces and horizontally in outdoors spaces.

Reference Standards

a. Certifications / Standards
• TS EN 12004
• CE
b. Ministry of Public Works and Settlement Item No.
Ministry of Public Works and Settlement Item No.: 04.013/1

Application Surfaces
Indoors Walls;
Cement based plaster
Indoors and Outdoors Floors;
Cement based plaster

Surface Preparation :
The application surface should be dry, clean, sound and dust free, and should have been cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as mortar and cement residues should be scraped from the application surface.
The dusty surface on the reverse side of the ceramic tile should be moisturized and cleaned.
The surface defects, which are deeper than 1 cm, should be repaired with MegaTamir İ or MegaTamir K 6-8 hours in advance of the adhesive mortar application. In the cases, where structural repair mortar should be used; MegaTamir İ Yapısal or MegaTamir K Yapısal should be preferred.
Upon the completion of the surface cleaning, MegaFilm primer should be applied in a single coat with a brush and be left to dry for 1 to 2 hours in order to enhance the bonding strength and stabilize the surface absorption.
In the case of wet space applications, waterproofing should be ensured with Megaİzo Lastik 10 on the surface, which should have been coated with the recommended primer, prior to ceramic flooring. Minimum class C2 adhesives should be preferred for such surfaces.

Application Methods :
BRUFIX should be applied to the surface with the notched trowel determined with respect to the size of the ceramic tile and the structural condition of the surface.
Due care must be taken to ensure that BRUFIX does not form a film layer on the surface during the application. In the cases of formation of film layer on the surface, the adhesive should be scraped off the surface and should never be used again.
The coating material should be placed on the surface and be ensured to settle thereon with a rubber tip hammer.
Joint filling should be initiated minimum 24 hours after the adhesion.
In the case of the applications with ceramic tiles with dimensions in excess of 20×20 cm in indoors and outdoors spaces; double-side adhesion should be applied.
The product should not be used for ceramic tiles for floors larger than 33×33 cm and for walls larger than 25×40 cm.

Application Recommendations :
MegaLatex may be employed in order to enhance the performance of the product.
The product should, once mixed, be used before the expiration of its pot life. Any mortar, the pot life of which has expired, should not be used during the application.
Any such foreign substance as lime, cement or plaster should not be added to the mortar prepared.
Any extra water should not be added to the mixture.
The product should not be applied on unsound surfaces. The soundness and the load bearing capacity of old surfaces should be checked prior to adhesion.
The surface should be preserved from air currents and water contact during and after the application.
The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing.
Due care should be taken to ensure that the material is not exposed to direct sunlight in hot weather conditions, and the product should be mixed with cold water.
The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance.
The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours.
Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +35°C whilst at application.

Close

MegaBlok Y192

Cement based, practical, manually applied gas concrete masonry mortar, containing workability enhancing chemical additives.

MegaBlok is used for the masonry on vertical surfaces of such construction elements as gas concrete and brick in indoors and outdoors spaces.

Reference Standards

a. Certifications / Standards
• TS EN 998 – 2
b. Ministry of Public Works and Settlement Item No.
Ministry of Public Works and Settlement Item No.: 04.478

Application Surfaces
Indoors and Outdoors Walls;
Gas concrete
Brick

Surface Preparation :
The application surface should be dry, clean, sound and dust free, and should have been cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as mortar and cement residues should be scraped from the application surface.
The surface should be checked and be leveled and smoothed in the event of any defects prior to masonry with construction elements such as gas concrete and brick.

Application Methods :
The MegaBlok mortar prepared should be spread properly and homogenously in equal thickness on the application surface with a trowel. The mortar should, then, be dredged with a 10×10 mm dredge to ensure uniform thickness in application.
During the masonry, the horizontal and vertical joint gaps should be allowed as 3 mm, and due care must be taken to ensure that the joint gaps are thoroughly filled with MegaBlok mortar.

Application Recommendations :
In the case of the applications at temperatures lower than +10° C; the product should be kept in a warm environment minimum one day prior to the application in order to ensure easy application, and it should be made sure that the product is at room temperature during the application.
The product may pose increased thickening in cold weather conditions. In such cases, the normal thickness of the product may be restored by being moved to a warm environment or bathed in hot water (having the materials kept in a container filled with hot water prior to mixing).
The product should, once mixed, be used before the expiration of its pot life. Any product, the pot life of which has expired, should not be used during the application. Epoxy based products have limited pot lives; therefore, due consideration should be given to the fact that the pot life and dry times would shorten at high temperatures and lengthen at low temperatures.
Any such foreign substance as lime, cement or plaster should not be added to the product, which prepared with two compounds.
The product should not be applied on unsound surfaces. The soundness and the load bearing capacity of old surfaces should be checked prior to adhesion.
The surface should be preserved from air currents and water contact during and after the application.
The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing.
Due care should be taken to ensure that the material is not exposed to direct sunlight in hot weather conditions.
The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance.
The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours.
Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +30°C whilst at application.

Close

MegaEpoxy D501

Epoxy resin based, double compound antibacterial ceramic adhesive and joint filler, which can be applied to joints, ranging between 3 and 15 mm, is resistant to acids and alkalis, has strong mechanical resistance and is suitable for contact with drinking water.

MegaEpoxy is used for the adhesion of antacid ceramic, industrial ceramic, granite, glass mosaic, glass brick and marble horizontally and vertically and the filling of horizontal and vertical joint gaps, ranging between 3 and 15 mm, in indoors and outdoors spaces on such floors with floor heating, where extremely high temperature changes occur, and in such spaces, where chemical resistance, impermeability and high mechanical resistance are required.
MegaEpoxy is fit for use in miscellaneous wet spaces and hygienic environments such as the food industry, milk, cheese and yogurt manufacturing shops, slaughter houses, dairy farms, integrated meat plants, wine distilleries and breweries, bottling and filling facilities, industrial kitchens, hospitals and laboratories, pharmaceutical and cosmetics industry, swimming pools containing salt and thermal water and waste water treatment plants.

Reference Standards

a. Certifications / Standards
• TS EN 13888
b. Ministry of Public Works and Settlement Item No.
Ministry of Public Works and Settlement Item No.: 04.013/2

Application Surfaces
Indoors and Outdoors Walls;
Ceramic
Natural stone
Marble
Granite
Glass mosaic
Glass brick
Cement based plaster
Concrete
Metal
Indoors and Outdoors Floors;
Ceramic
Natural stone
Marble
Granite
Glass mosaic
Glass brick
Cement based trowel coating
Concrete
Metal

Surface Preparation :
The application surface should be dry, clean, sound and dust free, and should have been cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as mortar and cement residues should be scraped from the application surface.
It should be made sure that the joint gaps are dry and clean prior to joint filling application.
Coating surface and joint gaps should have been cleaned and cleansed of oil, dirt and dust.
The concrete surfaces should have completed the 28 day curing period. The surface humidity should not exceed 5 % during the application.
Expansion joints should be formed as necessary with due consideration of the movements, which may occur on the floor especially in extensive spaces and in such environments, where heat sources exist, on account of thermal and mechanical causes. Such joints should be sealed with Megaİzo PU Mastik LM or Megaİzo PU Mastik HM.
Any surface defects deeper than 2 cm should be repaired with MegaTamir Epo 24 hours in advance of adhesive mortar application.
In the case of wet space applications, waterproofing should be ensured with Megaİzo Lastik 10 on the surface, which should have been coated with the recommended primer, prior to ceramic flooring.

Application Methods :
In the cases, where MegaEpoxy is to be used as adhesive; the material should, subsequent to stirring, be poured on the surface and be spread as a homogenous layer of 2 to 3 mm thickness. The product should be applied and spread with a notched trowel that is suitable for the ceramic size and the characteristics of the surface.
In the cases, where MegaEpoxy is to be used as joint filler; the stirred material should be applied only to the joint gaps on the application surface with a suitable epoxy joint trowel made of hard rubber. The product should, then, be scraped to ensure that the joints are filled and sealed completely and that the surface is free from any residue.
Any residues of the material on ceramics should be removed with warm water with detergent (30O C – 40O C) within 15 to 20 minutes following the application. Coarse cleaning should be performed with an epoxy trowel and the fine cleaning should be performed with a sponge. The fine cleaning should be performed with a moist sponge through circular movements without applying extreme pressure on the surface.
Joint filling may be initiated minimum 24 hours after the adhesion.
In some cases, a secondary application may be necessary to fill the joints, which have not been thoroughly filled and pose low levels. In such cases, the secondary application is recommended to be performed within maximum 5 to 6 hours in order to ensure inter coat adhesion.

Application Recommendations :
In the case of the applications at temperatures lower than +10° C; the product should be kept in a warm environment minimum one day prior to the application in order to ensure easy application, and it should be made sure that the product is at room temperature during the application.
The product may pose increased thickening in cold weather conditions. In such cases, the normal thickness of the product may be restored by being moved to a warm environment or bathed in hot water (having the materials kept in a container filled with hot water prior to mixing).
The product should, once mixed, be used before the expiration of its pot life. Any product, the pot life of which has expired, should not be used during the application. Epoxy based products have limited pot lives; therefore, due consideration should be given to the fact that the pot life and dry times would shorten at high temperatures and lengthen at low temperatures.
Any such foreign substance as lime, cement or plaster should not be added to the product, which prepared with two compounds.
The product should not be applied on unsound surfaces. The soundness and the load bearing capacity of old surfaces should be checked prior to adhesion.
The surface should be preserved from air currents and water contact during and after the application.
The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing.
Due care should be taken to ensure that the material is not exposed to direct sunlight in hot weather conditions, and the product should be mixed with cold water.
The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance.
The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours.
Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +10° C and +30°C whilst at application.
The surface temperature should be minimum +3°C higher than the related dew point temperature.
The product should not be applied under such conditions, where the ambient temperature is lower than +10°C and the relative humidity is higher than 75 %

Close

MegaFix Y101

Cement based ceramic tile adhesive mortar with reduced slippage and extended retention time.

MegaFix is used for the adhesion of coating materials in wall dimensions up to 25×40 cm and ceramic tile dimensions up to 33×33 cm horizontally and vertically in indoors spaces and horizontally in outdoors spaces on sound and dust free cement based plaster and trowel coating and prime coated concrete surfaces with low water absorption, and also for the adhesion of glass bricks in indoors spaces.

Reference Standards

a. Certifications / Standards
• TS EN 12004
• CE
• GEV Emicode EC1 Plus
b. Ministry of Public Works and Settlement Item No.
• Ministry of Public Works and Settlement Item No.: 04.013/1

Application Surfaces
Indoors Walls;
Cement based plaster
Concrete (MegaFilm or MegaFilm BB primer applied)
Indoors and Outdoors Floors;
Cement based plaster
Concrete (MegaFilm or MegaFilm BB primer applied)

Surface Preparation :
The application surface should be dry, clean, sound and dust free, and should have been cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as mortar and cement residues should be scraped from the application surface.
The dusty surface on the reverse side of the ceramic tile should be moisturized and cleaned.
The surface defects, which are deeper than 1 cm, should be repaired with MegaTamir İ or MegaTamir K 6-8 hours in advance of the adhesive mortar application. In the cases, where structural repair mortar should be used; MegaTamir İ Yapısal or MegaTamir K Yapısal should be preferred.
Upon the completion of the surface cleaning, MegaFilm primer should be applied in a single coat with a brush and be left to dry for 1 to 2 hours in order to enhance the bonding strength and stabilize the surface absorption.
Exposed concrete surfaces should be applied MegaFilm BB exposed concrete primer in single coat and be left to dry for minimum 3 hours prior to the application of the adhesive mortar in order to enhance the adhesion strength.
In the case of wet space applications, waterproofing should be ensured with Megaİzo Lastik 10 on the surface, prior to ceramic flooring. Minimum class C2 adhesives should be preferred for such surfaces.

Application Methods :
MegaFix should be applied to the surface with the notched trowel determined with respect to the size of the ceramic tile and the structural condition of the surface.
Due care must be taken to ensure that MegaFix does not form a film layer on the surface during the application. In the cases of formation of film layer on the surface, the adhesive should be scraped off the surface and should never be used again.
The coating material should be placed on the surface and be ensured to settle thereon with a rubber tip hammer.
Joint filling may be initiated minimum 24 hours after the adhesion.
In the case of the applications with ceramic tiles with dimensions in excess of 20×20 cm in indoors and outdoors spaces; double side adhesion should be applied.
The product should not be used for ceramic tiles for floors larger than 33×33 cm and for walls larger than 25×40 cm.

Application Recommendations :
The wall and floor ceramic tiles in light colors are recommended to be adhered with a colorful option of MegaFix.
MegaLatex may be employed in order to enhance the performance of the product.
The product should, once mixed, be used before the expiration of its pot life. Any mortar, the pot life of which has expired, should not be used during the application.
Any such foreign substance as lime, cement or plaster should not be added to the mortar prepared.
Any extra water should not be added to the mixture.
The product should not be applied on unsound surfaces. The soundness and the load bearing capacity of old surfaces should be checked prior to adhesion.
The surface should be preserved from air currents and water contact during and after the application.
The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing.
Due care should be taken to ensure that the material is not exposed to direct sunlight in hot weather conditions, and the product should be mixed with cold water.
The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance.
The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours.
Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +35°C whilst at application.

Close

MegaFix K Y106

Cement based thick bearing ceramic tile adhesive mortar with reduced slippage and extended retention time for uneven, defective surfaces.

MegaFix K is used for the adhesion of coating materials in wall dimensions up to 25×40 cm and ceramic tile dimensions up to 33×33 cm horizontally and vertically in indoors spaces and horizontally in outdoors spaces on sound and dust free cement based plaster and trowel coating and prime coated concrede surfaces with low water absorption. Minimizing the surface defects thanks to its thick filling, the product is used for the adhesion to floor of especially floor aplications such coating materials as marble, clinker and natural rock.

Reference Standards

a. Certifications / Standards
• TS EN 12004
• CE
b. Ministry of Public Works and Settlement Item No.
• Ministry of Public Works and Settlement Item No.: 04.013/1
• Ministry of Public Works and Settlement Item No.: 04.013/4

Application Surfaces
Indoors Walls;
Cement based plaster
Concrete (MegaFilm or MegaFilm BB primer applied)
Indoors and Outdoors Floors;
Cement based plaster
Concrete (MegaFilm or MegaFilm BB primer applied)

Surface Preparation :
The application surface should be dry, clean, sound and dust free, and should have been cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as mortar and cement residues should be scraped from the application surface.
The dusty surface on the reverse side of the ceramic tile should be moisturized and cleaned.
The surface defects, which are deeper than 1 cm, should be repaired with MegaTamir İ or MegaTamir K 6-8 hours in advance of the adhesive mortar application. In the cases, where structural repair mortar should be used; MegaTamir İ Yapısal or MegaTamir K Yapısal should be preferred.
Upon the completion of the surface cleaning, MegaFilm primer should be applied in a single coat with a brush and be left to dry for 1 to 2 hours in order to enhance the bonding strength and stabilize the surface absorption.
Exposed concrete surfaces should be applied MegaFilm BB exposed concrete primer in single coat and be left to dry for minimum 3 hours prior to the application of the adhesive mortar in order to enhance the adhesion strength.
In the case of wet space applications, waterproofing should be ensured with Megaİzo Lastik 10 on the surface, prior to ceramic flooring. Minimum class C2 adhesives should be preferred for such surfaces.

Application Methods :
MegaFix K should be applied to the surface with the notched trowel determined with respect to the size of the ceramic tile and the structural condition of the surface. should be applied to the surface with the notched trowel determined with respect to the size of the ceramic tile and the structural condition of the surface.
Due care must be taken to ensure that MegaFix does not form a film layer on the surface during the application. In the cases of formation of film layer on the surface, the adhesive should be scraped off the surface and should never be used again.
The coating material should be placed on the surface and be ensured to settle thereon with a rubber tip hammer.
Joint filling may be initiated minimum 24 hours after the adhesion.
In the case of the applications with ceramic tiles with dimensions in excess of 20×20 cm in indoors and outdoors spaces; double side adhesion should be applied.
The product should not be used for ceramic tiles for floors larger than 33×33 cm and for walls larger than 25×40 cm.

Application Recommendations :
The wall and floor ceramic tiles in light colors are recommended to be adhered with a colorful option of MegaFix.
MegaLatex may be employed in order to enhance the performance of the product.
The product should, once mixed, be used before the expiration of its pot life. Any mortar, the pot life of which has expired, should not be used during the application.
Any such foreign substance as lime, cement or plaster should not be added to the mortar prepared.
Any extra water should not be added to the mixture.
The product should not be applied on unsound surfaces. The soundness and the load bearing capacity of old surfaces should be checked prior to adhesion.
The surface should be preserved from air currents and water contact during and after the application.
The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing.
Due care should be taken to ensure that the material is not exposed to direct sunlight in hot weather conditions, and the product should be mixed with cold water.
The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance.
The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours.
Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +35°C whilst at application.

Close

MegaFlex Y103

Cement based thick bearing ceramic tile adhesive mortar with reduced slippage and extended retention time for uneven, defective surfaces.

MegaFix K is used for the adhesion of coating materials in wall dimensions up to 25×40 cm and ceramic tile dimensions up to 33×33 cm horizontally and vertically in indoors spaces and horizontally in outdoors spaces on sound and dust free cement based plaster and trowel coating and prime coated concrede surfaces with low water absorption. Minimizing the surface defects thanks to its thick filling, the product is used for the adhesion to floor of especially floor aplications such coating materials as marble, clinker and natural rock.

Reference Standards

a. Certifications / Standards
• TS EN 12004
• CE
b. Ministry of Public Works and Settlement Item No.
• Ministry of Public Works and Settlement Item No.: 04.013/1
• Ministry of Public Works and Settlement Item No.: 04.013/4

Application Surfaces
Indoors Walls;
Cement based plaster
Concrete (MegaFilm or MegaFilm BB primer applied)
Indoors and Outdoors Floors;
Cement based plaster
Concrete (MegaFilm or MegaFilm BB primer applied)

Surface Preparation :
The application surface should be dry, clean, sound and dust free, and should have been cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as mortar and cement residues should be scraped from the application surface.
The dusty surface on the reverse side of the ceramic tile should be moisturized and cleaned.
The surface defects, which are deeper than 1 cm, should be repaired with MegaTamir İ or MegaTamir K 6-8 hours in advance of the adhesive mortar application. In the cases, where structural repair mortar should be used; MegaTamir İ Yapısal or MegaTamir K Yapısal should be preferred.
Upon the completion of the surface cleaning, MegaFilm primer should be applied in a single coat with a brush and be left to dry for 1 to 2 hours in order to enhance the bonding strength and stabilize the surface absorption.
Exposed concrete surfaces should be applied MegaFilm BB exposed concrete primer in single coat and be left to dry for minimum 3 hours prior to the application of the adhesive mortar in order to enhance the adhesion strength.
In the case of wet space applications, waterproofing should be ensured with Megaİzo Lastik 10 on the surface, prior to ceramic flooring. Minimum class C2 adhesives should be preferred for such surfaces.

Application Methods :
MegaFix K should be applied to the surface with the notched trowel determined with respect to the size of the ceramic tile and the structural condition of the surface. should be applied to the surface with the notched trowel determined with respect to the size of the ceramic tile and the structural condition of the surface.
Due care must be taken to ensure that MegaFix does not form a film layer on the surface during the application. In the cases of formation of film layer on the surface, the adhesive should be scraped off the surface and should never be used again.
The coating material should be placed on the surface and be ensured to settle thereon with a rubber tip hammer.
Joint filling may be initiated minimum 24 hours after the adhesion.
In the case of the applications with ceramic tiles with dimensions in excess of 20×20 cm in indoors and outdoors spaces; double side adhesion should be applied.
The product should not be used for ceramic tiles for floors larger than 33×33 cm and for walls larger than 25×40 cm.

Application Recommendations :
The wall and floor ceramic tiles in light colors are recommended to be adhered with a colorful option of MegaFix.
MegaLatex may be employed in order to enhance the performance of the product.
The product should, once mixed, be used before the expiration of its pot life. Any mortar, the pot life of which has expired, should not be used during the application.
Any such foreign substance as lime, cement or plaster should not be added to the mortar prepared.
Any extra water should not be added to the mixture.
The product should not be applied on unsound surfaces. The soundness and the load bearing capacity of old surfaces should be checked prior to adhesion.
The surface should be preserved from air currents and water contact during and after the application.
The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing.
Due care should be taken to ensure that the material is not exposed to direct sunlight in hot weather conditions, and the product should be mixed with cold water.
The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance.
The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours.
Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +35°C whilst at application.

Close

MegaFlex Maxi Y104

Cement based thick bearing ceramic tile adhesive mortar with reduced slippage and extended retention time for uneven, defective surfaces.

MegaFix K is used for the adhesion of coating materials in wall dimensions up to 25×40 cm and ceramic tile dimensions up to 33×33 cm horizontally and vertically in indoors spaces and horizontally in outdoors spaces on sound and dust free cement based plaster and trowel coating and prime coated concrede surfaces with low water absorption. Minimizing the surface defects thanks to its thick filling, the product is used for the adhesion to floor of especially floor aplications such coating materials as marble, clinker and natural rock.

Reference Standards

a. Certifications / Standards
• TS EN 12004
• CE
b. Ministry of Public Works and Settlement Item No.
• Ministry of Public Works and Settlement Item No.: 04.013/1
• Ministry of Public Works and Settlement Item No.: 04.013/4

Application Surfaces
Indoors Walls;
Cement based plaster
Concrete (MegaFilm or MegaFilm BB primer applied)
Indoors and Outdoors Floors;
Cement based plaster
Concrete (MegaFilm or MegaFilm BB primer applied)

Surface Preparation :
The application surface should be dry, clean, sound and dust free, and should have been cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as mortar and cement residues should be scraped from the application surface.
The dusty surface on the reverse side of the ceramic tile should be moisturized and cleaned.
The surface defects, which are deeper than 1 cm, should be repaired with MegaTamir İ or MegaTamir K 6-8 hours in advance of the adhesive mortar application. In the cases, where structural repair mortar should be used; MegaTamir İ Yapısal or MegaTamir K Yapısal should be preferred.
Upon the completion of the surface cleaning, MegaFilm primer should be applied in a single coat with a brush and be left to dry for 1 to 2 hours in order to enhance the bonding strength and stabilize the surface absorption.
Exposed concrete surfaces should be applied MegaFilm BB exposed concrete primer in single coat and be left to dry for minimum 3 hours prior to the application of the adhesive mortar in order to enhance the adhesion strength.
In the case of wet space applications, waterproofing should be ensured with Megaİzo Lastik 10 on the surface, prior to ceramic flooring. Minimum class C2 adhesives should be preferred for such surfaces.

Application Methods :
MegaFix K should be applied to the surface with the notched trowel determined with respect to the size of the ceramic tile and the structural condition of the surface. should be applied to the surface with the notched trowel determined with respect to the size of the ceramic tile and the structural condition of the surface.
Due care must be taken to ensure that MegaFix does not form a film layer on the surface during the application. In the cases of formation of film layer on the surface, the adhesive should be scraped off the surface and should never be used again.
The coating material should be placed on the surface and be ensured to settle thereon with a rubber tip hammer.
Joint filling may be initiated minimum 24 hours after the adhesion.
In the case of the applications with ceramic tiles with dimensions in excess of 20×20 cm in indoors and outdoors spaces; double side adhesion should be applied.
The product should not be used for ceramic tiles for floors larger than 33×33 cm and for walls larger than 25×40 cm.

Application Recommendations :
The wall and floor ceramic tiles in light colors are recommended to be adhered with a colorful option of MegaFix.
MegaLatex may be employed in order to enhance the performance of the product.
The product should, once mixed, be used before the expiration of its pot life. Any mortar, the pot life of which has expired, should not be used during the application.
Any such foreign substance as lime, cement or plaster should not be added to the mortar prepared.
Any extra water should not be added to the mixture.
The product should not be applied on unsound surfaces. The soundness and the load bearing capacity of old surfaces should be checked prior to adhesion.
The surface should be preserved from air currents and water contact during and after the application.
The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing.
Due care should be taken to ensure that the material is not exposed to direct sunlight in hot weather conditions, and the product should be mixed with cold water.
The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance.
The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours.
Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +35°C whilst at application.

Close

MegaGranit Y102

Cement based thick bearing ceramic tile adhesive mortar with reduced slippage and extended retention time for uneven, defective surfaces.

MegaFix K is used for the adhesion of coating materials in wall dimensions up to 25×40 cm and ceramic tile dimensions up to 33×33 cm horizontally and vertically in indoors spaces and horizontally in outdoors spaces on sound and dust free cement based plaster and trowel coating and prime coated concrede surfaces with low water absorption. Minimizing the surface defects thanks to its thick filling, the product is used for the adhesion to floor of especially floor aplications such coating materials as marble, clinker and natural rock.

Reference Standards

a. Certifications / Standards
• TS EN 12004
• CE
b. Ministry of Public Works and Settlement Item No.
• Ministry of Public Works and Settlement Item No.: 04.013/1
• Ministry of Public Works and Settlement Item No.: 04.013/4

Application Surfaces
Indoors Walls;
Cement based plaster
Concrete (MegaFilm or MegaFilm BB primer applied)
Indoors and Outdoors Floors;
Cement based plaster
Concrete (MegaFilm or MegaFilm BB primer applied)

Surface Preparation :
The application surface should be dry, clean, sound and dust free, and should have been cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as mortar and cement residues should be scraped from the application surface.
The dusty surface on the reverse side of the ceramic tile should be moisturized and cleaned.
The surface defects, which are deeper than 1 cm, should be repaired with MegaTamir İ or MegaTamir K 6-8 hours in advance of the adhesive mortar application. In the cases, where structural repair mortar should be used; MegaTamir İ Yapısal or MegaTamir K Yapısal should be preferred.
Upon the completion of the surface cleaning, MegaFilm primer should be applied in a single coat with a brush and be left to dry for 1 to 2 hours in order to enhance the bonding strength and stabilize the surface absorption.
Exposed concrete surfaces should be applied MegaFilm BB exposed concrete primer in single coat and be left to dry for minimum 3 hours prior to the application of the adhesive mortar in order to enhance the adhesion strength.
In the case of wet space applications, waterproofing should be ensured with Megaİzo Lastik 10 on the surface, prior to ceramic flooring. Minimum class C2 adhesives should be preferred for such surfaces.

Application Methods :
MegaFix K should be applied to the surface with the notched trowel determined with respect to the size of the ceramic tile and the structural condition of the surface. should be applied to the surface with the notched trowel determined with respect to the size of the ceramic tile and the structural condition of the surface.
Due care must be taken to ensure that MegaFix does not form a film layer on the surface during the application. In the cases of formation of film layer on the surface, the adhesive should be scraped off the surface and should never be used again.
The coating material should be placed on the surface and be ensured to settle thereon with a rubber tip hammer.
Joint filling may be initiated minimum 24 hours after the adhesion.
In the case of the applications with ceramic tiles with dimensions in excess of 20×20 cm in indoors and outdoors spaces; double side adhesion should be applied.
The product should not be used for ceramic tiles for floors larger than 33×33 cm and for walls larger than 25×40 cm.

Application Recommendations :
The wall and floor ceramic tiles in light colors are recommended to be adhered with a colorful option of MegaFix.
MegaLatex may be employed in order to enhance the performance of the product.
The product should, once mixed, be used before the expiration of its pot life. Any mortar, the pot life of which has expired, should not be used during the application.
Any such foreign substance as lime, cement or plaster should not be added to the mortar prepared.
Any extra water should not be added to the mixture.
The product should not be applied on unsound surfaces. The soundness and the load bearing capacity of old surfaces should be checked prior to adhesion.
The surface should be preserved from air currents and water contact during and after the application.
The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing.
Due care should be taken to ensure that the material is not exposed to direct sunlight in hot weather conditions, and the product should be mixed with cold water.
The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance.
The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours.
Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +35°C whilst at application.

Close

MegaPool Y105

Cement based thick bearing ceramic tile adhesive mortar with reduced slippage and extended retention time for uneven, defective surfaces.

MegaFix K is used for the adhesion of coating materials in wall dimensions up to 25×40 cm and ceramic tile dimensions up to 33×33 cm horizontally and vertically in indoors spaces and horizontally in outdoors spaces on sound and dust free cement based plaster and trowel coating and prime coated concrede surfaces with low water absorption. Minimizing the surface defects thanks to its thick filling, the product is used for the adhesion to floor of especially floor aplications such coating materials as marble, clinker and natural rock.

Reference Standards

a. Certifications / Standards
• TS EN 12004
• CE
b. Ministry of Public Works and Settlement Item No.
• Ministry of Public Works and Settlement Item No.: 04.013/1
• Ministry of Public Works and Settlement Item No.: 04.013/4

Application Surfaces
Indoors Walls;
Cement based plaster
Concrete (MegaFilm or MegaFilm BB primer applied)
Indoors and Outdoors Floors;
Cement based plaster
Concrete (MegaFilm or MegaFilm BB primer applied)

Surface Preparation :
The application surface should be dry, clean, sound and dust free, and should have been cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as mortar and cement residues should be scraped from the application surface.
The dusty surface on the reverse side of the ceramic tile should be moisturized and cleaned.
The surface defects, which are deeper than 1 cm, should be repaired with MegaTamir İ or MegaTamir K 6-8 hours in advance of the adhesive mortar application. In the cases, where structural repair mortar should be used; MegaTamir İ Yapısal or MegaTamir K Yapısal should be preferred.
Upon the completion of the surface cleaning, MegaFilm primer should be applied in a single coat with a brush and be left to dry for 1 to 2 hours in order to enhance the bonding strength and stabilize the surface absorption.
Exposed concrete surfaces should be applied MegaFilm BB exposed concrete primer in single coat and be left to dry for minimum 3 hours prior to the application of the adhesive mortar in order to enhance the adhesion strength.
In the case of wet space applications, waterproofing should be ensured with Megaİzo Lastik 10 on the surface, prior to ceramic flooring. Minimum class C2 adhesives should be preferred for such surfaces.

Application Methods :
MegaFix K should be applied to the surface with the notched trowel determined with respect to the size of the ceramic tile and the structural condition of the surface. should be applied to the surface with the notched trowel determined with respect to the size of the ceramic tile and the structural condition of the surface.
Due care must be taken to ensure that MegaFix does not form a film layer on the surface during the application. In the cases of formation of film layer on the surface, the adhesive should be scraped off the surface and should never be used again.
The coating material should be placed on the surface and be ensured to settle thereon with a rubber tip hammer.
Joint filling may be initiated minimum 24 hours after the adhesion.
In the case of the applications with ceramic tiles with dimensions in excess of 20×20 cm in indoors and outdoors spaces; double side adhesion should be applied.
The product should not be used for ceramic tiles for floors larger than 33×33 cm and for walls larger than 25×40 cm.

Application Recommendations :
The wall and floor ceramic tiles in light colors are recommended to be adhered with a colorful option of MegaFix.
MegaLatex may be employed in order to enhance the performance of the product.
The product should, once mixed, be used before the expiration of its pot life. Any mortar, the pot life of which has expired, should not be used during the application.
Any such foreign substance as lime, cement or plaster should not be added to the mortar prepared.
Any extra water should not be added to the mixture.
The product should not be applied on unsound surfaces. The soundness and the load bearing capacity of old surfaces should be checked prior to adhesion.
The surface should be preserved from air currents and water contact during and after the application.
The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing.
Due care should be taken to ensure that the material is not exposed to direct sunlight in hot weather conditions, and the product should be mixed with cold water.
The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance.
The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours.
Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +35°C whilst at application.

Close

MegaPro Facade Y111

Cement based thick bearing ceramic tile adhesive mortar with reduced slippage and extended retention time for uneven, defective surfaces.

MegaFix K is used for the adhesion of coating materials in wall dimensions up to 25×40 cm and ceramic tile dimensions up to 33×33 cm horizontally and vertically in indoors spaces and horizontally in outdoors spaces on sound and dust free cement based plaster and trowel coating and prime coated concrede surfaces with low water absorption. Minimizing the surface defects thanks to its thick filling, the product is used for the adhesion to floor of especially floor aplications such coating materials as marble, clinker and natural rock.

Reference Standards

a. Certifications / Standards
• TS EN 12004
• CE
b. Ministry of Public Works and Settlement Item No.
• Ministry of Public Works and Settlement Item No.: 04.013/1
• Ministry of Public Works and Settlement Item No.: 04.013/4

Application Surfaces
Indoors Walls;
Cement based plaster
Concrete (MegaFilm or MegaFilm BB primer applied)
Indoors and Outdoors Floors;
Cement based plaster
Concrete (MegaFilm or MegaFilm BB primer applied)

Surface Preparation :
The application surface should be dry, clean, sound and dust free, and should have been cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as mortar and cement residues should be scraped from the application surface.
The dusty surface on the reverse side of the ceramic tile should be moisturized and cleaned.
The surface defects, which are deeper than 1 cm, should be repaired with MegaTamir İ or MegaTamir K 6-8 hours in advance of the adhesive mortar application. In the cases, where structural repair mortar should be used; MegaTamir İ Yapısal or MegaTamir K Yapısal should be preferred.
Upon the completion of the surface cleaning, MegaFilm primer should be applied in a single coat with a brush and be left to dry for 1 to 2 hours in order to enhance the bonding strength and stabilize the surface absorption.
Exposed concrete surfaces should be applied MegaFilm BB exposed concrete primer in single coat and be left to dry for minimum 3 hours prior to the application of the adhesive mortar in order to enhance the adhesion strength.
In the case of wet space applications, waterproofing should be ensured with Megaİzo Lastik 10 on the surface, prior to ceramic flooring. Minimum class C2 adhesives should be preferred for such surfaces.

Application Methods :
MegaFix K should be applied to the surface with the notched trowel determined with respect to the size of the ceramic tile and the structural condition of the surface. should be applied to the surface with the notched trowel determined with respect to the size of the ceramic tile and the structural condition of the surface.
Due care must be taken to ensure that MegaFix does not form a film layer on the surface during the application. In the cases of formation of film layer on the surface, the adhesive should be scraped off the surface and should never be used again.
The coating material should be placed on the surface and be ensured to settle thereon with a rubber tip hammer.
Joint filling may be initiated minimum 24 hours after the adhesion.
In the case of the applications with ceramic tiles with dimensions in excess of 20×20 cm in indoors and outdoors spaces; double side adhesion should be applied.
The product should not be used for ceramic tiles for floors larger than 33×33 cm and for walls larger than 25×40 cm.

Application Recommendations :
The wall and floor ceramic tiles in light colors are recommended to be adhered with a colorful option of MegaFix.
MegaLatex may be employed in order to enhance the performance of the product.
The product should, once mixed, be used before the expiration of its pot life. Any mortar, the pot life of which has expired, should not be used during the application.
Any such foreign substance as lime, cement or plaster should not be added to the mortar prepared.
Any extra water should not be added to the mixture.
The product should not be applied on unsound surfaces. The soundness and the load bearing capacity of old surfaces should be checked prior to adhesion.
The surface should be preserved from air currents and water contact during and after the application.
The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing.
Due care should be taken to ensure that the material is not exposed to direct sunlight in hot weather conditions, and the product should be mixed with cold water.
The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance.
The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours.
Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +35°C whilst at application.

Close

MegaPro Full Y114

Cement based thick bearing ceramic tile adhesive mortar with reduced slippage and extended retention time for uneven, defective surfaces.

MegaFix K is used for the adhesion of coating materials in wall dimensions up to 25×40 cm and ceramic tile dimensions up to 33×33 cm horizontally and vertically in indoors spaces and horizontally in outdoors spaces on sound and dust free cement based plaster and trowel coating and prime coated concrede surfaces with low water absorption. Minimizing the surface defects thanks to its thick filling, the product is used for the adhesion to floor of especially floor aplications such coating materials as marble, clinker and natural rock.

Reference Standards

a. Certifications / Standards
• TS EN 12004
• CE
b. Ministry of Public Works and Settlement Item No.
• Ministry of Public Works and Settlement Item No.: 04.013/1
• Ministry of Public Works and Settlement Item No.: 04.013/4

Application Surfaces
Indoors Walls;
Cement based plaster
Concrete (MegaFilm or MegaFilm BB primer applied)
Indoors and Outdoors Floors;
Cement based plaster
Concrete (MegaFilm or MegaFilm BB primer applied)

Surface Preparation :
The application surface should be dry, clean, sound and dust free, and should have been cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as mortar and cement residues should be scraped from the application surface.
The dusty surface on the reverse side of the ceramic tile should be moisturized and cleaned.
The surface defects, which are deeper than 1 cm, should be repaired with MegaTamir İ or MegaTamir K 6-8 hours in advance of the adhesive mortar application. In the cases, where structural repair mortar should be used; MegaTamir İ Yapısal or MegaTamir K Yapısal should be preferred.
Upon the completion of the surface cleaning, MegaFilm primer should be applied in a single coat with a brush and be left to dry for 1 to 2 hours in order to enhance the bonding strength and stabilize the surface absorption.
Exposed concrete surfaces should be applied MegaFilm BB exposed concrete primer in single coat and be left to dry for minimum 3 hours prior to the application of the adhesive mortar in order to enhance the adhesion strength.
In the case of wet space applications, waterproofing should be ensured with Megaİzo Lastik 10 on the surface, prior to ceramic flooring. Minimum class C2 adhesives should be preferred for such surfaces.

Application Methods :
MegaFix K should be applied to the surface with the notched trowel determined with respect to the size of the ceramic tile and the structural condition of the surface. should be applied to the surface with the notched trowel determined with respect to the size of the ceramic tile and the structural condition of the surface.
Due care must be taken to ensure that MegaFix does not form a film layer on the surface during the application. In the cases of formation of film layer on the surface, the adhesive should be scraped off the surface and should never be used again.
The coating material should be placed on the surface and be ensured to settle thereon with a rubber tip hammer.
Joint filling may be initiated minimum 24 hours after the adhesion.
In the case of the applications with ceramic tiles with dimensions in excess of 20×20 cm in indoors and outdoors spaces; double side adhesion should be applied.
The product should not be used for ceramic tiles for floors larger than 33×33 cm and for walls larger than 25×40 cm.

Application Recommendations :
The wall and floor ceramic tiles in light colors are recommended to be adhered with a colorful option of MegaFix.
MegaLatex may be employed in order to enhance the performance of the product.
The product should, once mixed, be used before the expiration of its pot life. Any mortar, the pot life of which has expired, should not be used during the application.
Any such foreign substance as lime, cement or plaster should not be added to the mortar prepared.
Any extra water should not be added to the mixture.
The product should not be applied on unsound surfaces. The soundness and the load bearing capacity of old surfaces should be checked prior to adhesion.
The surface should be preserved from air currents and water contact during and after the application.
The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing.
Due care should be taken to ensure that the material is not exposed to direct sunlight in hot weather conditions, and the product should be mixed with cold water.
The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance.
The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours.
Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595)

Surface and Ambient Temperature
The surface and ambient temperature should be between +5°C and +35°C whilst at application.